Modelación de la transferencia de oxágeno en sistemas de aereación mediante un modelo de dos zonas simplificado
Loading...
Authors
Durán Herrera, Esteban
Rojas Meza, Gerardo
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
A new two zone simplified oxygen mass-transfer model with an analytical solution was proposed and used to analyze the unsteady state reaeration data of diffused reaeration systems in order to find the volumetric mass-transfer coefficients. Series of unsteady state reaeration tests in a 1000 l tank was performed to validate the model. The effect of the air flow rate and the temperature upon the mass-transfer coefficients was studied and empirical equations were used to successfully correlate them. The air flow rate was varied from 0,50 to 1,33 - 10-3 normal m3/s and the water temperature was varied from 293,25 to 303,25 K. It was found that the new model describes mathematically the aeration process very well and gives a better physical understanding of it.
Description
Keywords
Citation
http://revistas.ucr.ac.cr/index.php/cienciaytecnologia/article/view/2641