Mostrar el registro sencillo del ítem

dc.creatorMatamoros Hidalgo, Adolfo
dc.creatorSantana Barboza, Guillermo
dc.date.accessioned2022-08-11T21:36:00Z
dc.date.available2022-08-11T21:36:00Z
dc.date.issued1991-07
dc.identifier.citationhttps://issuu.com/guillermosantana/docs/reporte_inii-56-90/1es_ES
dc.identifier.isbn9977-15-010-9
dc.identifier.urihttps://hdl.handle.net/10669/87173
dc.description.abstractEn el presente trabajo se hace un análisis dinámico de los edificios de la Facultad de Microbioloqía de la Universidad de Costa Rica, con el fin de poder determinar si satisfacen los requerimientos establecidos por el Código Sísmico de Costa Rica. Además se llevaron a cabo varios análisis estructurales, empleando registros de los sismos de: Golfito, Costa Rica (1983), registrado en la base del Instituto Nacional de Seguros en San Jose; San Salvador, El Salvador (1986), registrado en el Instituto Geográfico Nacional; Loma Prieta, California (1989), registrado en la estación de campo libre de Corralitos. Se utilizaron estos registros con el fin de estimar el nivel de daños en la estructura en caso de verse sometida a diferentes excitaciones sísmicas. Otro parámetro de comparación es el análisis de sismo utilizando el espectro de diseño para estructuras del Tipo 3 que aporta el Código Sísmico de Costa Rica. En la modelación de la estructura se tomaron en cuenta los efectos que inducen las paredes de mampostería al reducir la longitud efectiva de las columnas, y el efecto distorsionador de elementos estructurales no tomados en cuenta en el proceso de diseño. Se relatan los resultados obtenidos con las diferentes excitaciones sísmicas y se establecen comparaciones entre ellos. Como conclusión del trabajo se resalta la posibilidad de un sismo poco profunda y cercano al Valle Central, la vulnerabilidad de las estructuras similares a esta, y las consecuencias puede acarrear esto al país.es_ES
dc.description.abstractThe object of this paper is to make a dynamic analysis of the Faculty of Microbiology buildings at campus of the University of Costa Rica. The main purpose is to determine if they comply with the requirements established by the current Costa Rican Seismic Code. Various dynamic analysis were performed, us.ing the accelerograms from the following earthquakes: Golfito, Costa Rica (1983), recorded at the basement of the National Insurance Institute in downtown, San Jose; San Salvador, El Salvador (1986), recorded at the National Geographic Institute; Loma Prieta, California (1989), recorded at the free field station in Corralitos. These analyses were intended to estimate the damage suffered by the structure when submitted to different seismic forces. Another comparison is made using the design spectra specified by the Costa Rica's Seismic Code, for type three structures. In the structure's model the effects of distorting elements like masonry walls, walls reducing the effective length of columns and the elevator's shaft walls were taken into account. The results obtained with the various seismic excitations is discussed. Finally, the paper underlines the possibility of a superficial earthquake near the Central Valley, the vulnerability of structures similar to the one considered in this case and the consequences it can bring to the country.es_ES
dc.description.sponsorshipUniversidad de Costa Rica/[]/UCR/Costa Ricaes_ES
dc.language.isospaes_ES
dc.sourceQuinto seminario de Ingeniería Estructural. 22-24 de noviembre de 1990. San José, Costa Rica: Universidad de Costa Ricaes_ES
dc.subjectDynamic structural analisyses_ES
dc.subjectCosta Rica seismic codees_ES
dc.subjectExisting buildingses_ES
dc.subjectSeismic vulnerabilityes_ES
dc.subjectSISMOes_ES
dc.titleAnálisis dinámico de los edificios de Microbiología de la Universidad de Costa Ricaes_ES
dc.typecomunicación de congresoes_ES
dc.description.procedenceUCR::Vicerrectoría de Investigación::Unidades de Investigación::Ingeniería::Instituto Investigaciones en Ingeniería (INII)es_ES